Questions? Give Us A Call (843) 517-8180

Superior Building Performance with DELTA®-VENT S: Your Ultimate Weather-Resistive Barrier & Air Barrier Solution

Posted by Spycor Building on Jul 21st 2025

Moisture intrusion and air leaks in commercial wall systems can lead to costly issues like mold growth, structural damage, and reduced energy efficiency. Contractors and builders often struggle with selecting and installing a reliable air and water-resistive barrier that balances moisture management with vapor permeability. Improper installation can exacerbate these problems, leading to compromised building envelopes and frustrated project managers. These pain points can delay projects, increase costs, and harm a contractor’s reputation.

The Solution: DELTA®-VENT S is a high-performance air and water-resistive barrier designed to address these challenges. Its advanced vapor-permeable technology protects commercial walls from moisture while allowing vapor to escape, ensuring a durable and energy-efficient building envelope. This step-by-step video guide and downloadable resources will empower contractors to install DELTA®-VENT S correctly, saving time and ensuring long-term performance.

The DELTA®-VENT S Advantage: Dual-

Action Protection for Unrivaled

Performance

DELTA®-VENT S is not just a house wrap; it's a sophisticated, 3-layer vapor-permeable membrane engineered to optimize your building's envelope performance. It masterfully combines two critical functions – acting as a primary Weather-Resistive Barrier that aggressively sheds bulk water, and a robust Air Barrier that prevents uncontrolled airflow. Concurrently, its high vapor permeability allows internal moisture vapor to escape, ensuring walls can "breathe" and dry effectively.

This dual-action approach is key to achieving truly superior building performance:

  • Exceptional Weather-Resistive Barrier: DELTA®-VENT S creates an unyielding shield against wind-driven rain and external moisture. Its watertight properties ensure that liquid water is kept out of your wall assembly, protecting sheathing, insulation, and framing from moisture damage. This is your first and most critical line of defense against the elements.
  • Robust Air Barrier Solution: Uncontrolled air leakage is a major culprit in energy waste and discomfort. DELTA®-VENT S forms a continuous, airtight layer around your building. By significantly reducing air infiltration and exfiltration, it minimizes drafts, stabilizes indoor temperatures, and drastically cuts down on heating and cooling costs. This directly translates to enhanced energy efficiency and a more comfortable interior environment.
  • Intelligent Moisture Management (Vapor Permeability): While stopping liquid water and air, DELTA®-VENT S is highly vapor permeable. This means it allows water vapor that might accumulate within the wall cavity (from indoor humidity or construction moisture) to diffuse outwards. This crucial feature prevents condensation, mitigating the risk of mold growth, rot, and deterioration of building materials.
  • Unmatched Durability and Longevity: Constructed from high-strength spun-bonded polypropylene, DELTA®-VENT S is incredibly tear-resistant and durable. It withstands the rigors of construction sites, resists punctures, and maintains its integrity over time. This ensures long-term, reliable performance, protecting your investment for decades.

By integrating DELTA®-VENT S, you're not just adding a component; you're implementing a foundational system that elevates your building to a new standard of performance, comfort, and sustainability.

For more detailed information, please refer to the official product page:
https://www.dorken.com/en/our-products/products/commercial/delta-vent-s-wall.php

Download the full installation guide here for detailed instructions and diagrams:
DELTA®-VENT S Installation Instructions


Technical Data: Access detailed technical specifications and performance data.
https://www.dorken.com/media/docs/products/Technical-Data/DELTA-VENT-S_WRB-Technical-Data.pdf

Frequently Asked Questions (FAQ)

 

Q: What is DELTA®-VENT S used for in building construction?
DELTA®-VENT S is a high-performance, vapor-permeable water-resistive barrier (WRB) and air barrier used in exterior wall assemblies to prevent moisture intrusion and air leakage, while allowing interior moisture vapor to escape.

Q: How does DELTA®-VENT S contribute to energy efficiency?
It maximizes airtightness in the building enclosure, which significantly reduces heat loss or gain due to air leakage, leading to improved energy efficiency and lower heating and cooling costs.

Q: Is DELTA®-VENT S breathable?
Yes, DELTA®-VENT S is highly vapor permeable, with a permeance of 50 perms, allowing moisture vapor from inside the building to diffuse outwards, preventing condensation within the wall assembly.

Q: What is the UV exposure limit for DELTA®-VENT S?
DELTA®-VENT S can be exposed to UV radiation for up to one year (365 days in Climate Zone 3 and above) before being covered by exterior cladding, offering extended flexibility during construction.

Q: Is DELTA®-VENT S compatible with common building codes?
Yes, it is NFPA 285 compliant and approved under the International Building Code (IBC) and International Residential Code (IRC) (ICC ESR-2932), meeting stringent industry standards.

Q: What are the key components of DELTA®-VENT S?
It is a three-layer membrane consisting of two outer layers of high-strength, spun-bonded polypropylene and a highly vapor-permeable, watertight TPU middle layer.

Q: How is DELTA®-VENT S installed around windows and penetrations?  Installation around windows and penetrations involves using compatible DELTA® accessories like DELTA-FAS CORNER, DELTA-FLASHING, DELTA-MULTI BAND, DELTA-TILAXX, or DELTA-LFS to ensure a continuous air and water-tight seal.